Designed for Commercial A/V Installations in 220V-240V regions, the CN3600 SE combines robust control capabilities via SmartSequencing Technology, advanced AC protection, and AC noise filtration.
Family: Contractor Series 240V
Line Voltage: 240 Volts
AC Voltage Input Range: 180-270VAC, 50/60Hz
AC Cord: 1.5mm² x 3, 2.5m Long, black, IEC C19 Female to Schuko CEE 7/7 Male Plug
Rear Panel Outlets: 1 IEC C13 pair (Unswitched), 3 IEC C13 pairs (Sequenced, each pair controlled by separate relay)
Front Panel: 1 IEC C13 (Unswitched)
Surge/Under-Overvoltage Protection: AC Surge Protection Series Multi-Stage Protection SMP
Spike Protection Mode: Line to neutral, zero ground leakage
Spike Clamping Voltage: 375V peak @ 6,000 volts/3,000 amps
Response Time: 1 nanosecond
Maximum Surge Current: 6,500 Amps
AC Undervoltage Protection: EVS, 175VAC±3VAC
AC Overvoltage Protection: EVS, 275VAC±5VAC
AC Overvoltage Reset Modes: Manual and Auto-reset (configurable)
AC Filtering: LiFT
Noise Attenuation: Linear, 10dB @10KHz, 40dB @100KHz, 50dB @500KHz
Operating Temperature Range: 5°C (40°F) to 40°C (105°F)
Humidity Range: <90% rH (Relative Humidity)
Keyswitch: Front panel, 3-position keyswitch (On, Off, Remote)
Keys: Included, 1 pair
Pushbutton Switch: Front panel, hidden by security cover
Circuit Breaker: Front panel, pushbutton, 20A Thermal Breaker
Front Panel Diagnostic Indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage
Front Panel DIP Switches: Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off, BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
Potentiometer: Front panel, hidden by security cover, fine-tune delay adjust
Control/Status/Triggering (Rear Panel): Remote Terminal +5-30VDC In, 12VDC (12mA) Out
SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop – 1000’ nominal)
Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring)
Force Off/Delay 3 Terminal: Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring)
RS-232 Compatible: Yes, DB-9 Connector
Voltmeter: Available with RS-232, ± 2VAC accuracy
Ammeter: Available with RS-232, ±1A accuracy
Power Consumption (No Load): 10 Watts
Safety Agency: NRTL-C, RoHS Compliant